Monchrui

MONCHRUI . Your reliable HVAC partner!

Description

Single‑Unit Containerized Modular Data Center Prefabricated Outdoor Container IDC Computer Room (Single‑Unit Containerized Data Center)

Single‑Unit Containerized Modular Data Center Prefabricated Outdoor Container IDC Computer Room
Single‑Unit Containerized Modular Data Center Prefabricated Outdoor Container IDC Computer Room
Single‑Unit Containerized Modular Data Center Prefabricated Outdoor Container IDC Computer Room
Single‑Unit Containerized Modular Data Center Prefabricated Outdoor Container IDC Computer Room
Single‑Unit Containerized Modular Data Center Prefabricated Outdoor Container IDC Computer Room
Single‑Unit Containerized Modular Data Center Prefabricated Outdoor Container IDC Computer Room
Single‑Unit Containerized Modular Data Center Prefabricated Outdoor Container IDC Computer Room
Single‑Unit Containerized Modular Data Center Prefabricated Outdoor Container IDC Computer Room
Single‑Unit Containerized Modular Data Center Prefabricated Outdoor Container IDC Computer Room

Single‑unit containerized data center is a fully‑integrated modular IDC computer‑room unit built on standard shipping‑container shell. All equipment including server racks, precision cooling, UPS power supply & distribution, busbar, gas fire‑suppression, environment & security monitoring are fully assembled and pre‑commissioned inside factory. After on‑site delivery, it can go into production rapidly once external water and power are connected.

Air‑cooled and water‑cooled cooling solutions are optional. Internal hot‑aisle / cold‑aisle containment optimizes PUE performance. The container shell is rain‑proof, dust‑proof and anti‑corrosive for bare‑ground outdoor deployment. Complete safety functions: clean‑agent gas fire suppression, access control, CCTV, smoke detector, water‑leak & temperature‑humidity monitoring & alarm. It can work standalone or expand computing capacity by parallel stacking multiple containers. Optional photovoltaic input for off‑grid remote sites. Target use‑cases include edge computing, disaster backup, field‑site computing and temporary capacity expansion. Turn‑key project service is available.

Main Selection Parameters for Single‑Unit Container Data Center

Item

Standard Base Specification

Customizable Options

Container Shell

Standard 20ft / 40ft shipping container

Non‑standard dimension, upgraded ingress protection

Per‑Rack Power Density

3‑8 kW per rack

Custom up to 15kW high‑density rack

Cooling Solution

Air‑cooled precision air‑conditioner

Water‑cooled indirect evaporative cooling

Server Rack Quantity

6‑24 standard server racks

Adjustable rack count on demand

Power System

UPS, input / output PDU, bus‑bar distribution

Add PV photovoltaic module, diesel generator interface

Fire Protection

HFC‑227ea clean gas fire suppression

Alternative clean‑agent fire‑extinguishing solution

Monitoring Platform

DCIM environment monitoring with remote alarm

Connect to customer third‑party O&M platform

Deployment Environment

Outdoor rain‑proof dust‑proof anti‑corrosion

Reinforced shell for extreme cold / high‑corrosion sites

Delivery Mode

Factory pre‑assembled & pre‑tested

Turn‑key service: design‑manufacture‑on‑site commissioning

Integrated Sub‑Systems Inside Container

Sub‑System

Functional Description

Server Rack Sub‑System

Standard IT server racks, PDU power supply, cable management for hardware hosting

Cooling Sub‑System

Air‑cooled / water‑cooled precision AC; hot‑cold aisle containment for PUE optimization & stable indoor temperature‑humidity

Power Distribution Sub‑System

UPS uninterruptible power supply, input / output distribution cabinet, bus‑bar system to guarantee continuous IT power

Fire‑Suppression Sub‑System

HFC‑227ea clean gas extinguishing, smoke alarm, power cut‑off linkage in fire event

Security & DCIM Sub‑System

Access control, CCTV, smoke / water‑leak / T‑H sensors. DCIM platform for remote monitoring & alarm push

Container Enclosure

Rain‑dust‑corrosion resistant housing; cable entry ports, maintenance doors, ventilation protective structure

Seven Core Product Advantages

  1. Factory pre‑assembly & pre‑test greatly shorten project timeline All assembly, wiring and system joint‑debug are completed in factory. Only water‑power connection required on‑site. Avoid long‑term civil‑work and fragmented on‑site installation of traditional computer‑room.

  2. Hot‑cold aisle containment optimize PUE & cut operating energy cost Internal hot‑cold aisle sealing reduces mixed‑air energy loss. Air‑cooled or water‑cooled options available to match target PUE and lower long‑term electricity expense.

  3. Direct outdoor deployment for complex site conditions Anti‑rain / dust / corrosion container enclosure, no purpose‑built building required. Can be deployed on open‑air ground, mining sites and oil‑gas stations.

  4. Modular elastic capacity expansion Single container works as complete independent IDC unit. Add more parallel‑stacked containers for growing computing requirement without heavy upfront civil‑work investment.

  5. Comprehensive safety protection for reliable IT operation Integrated clean‑gas fire suppression, smoke, water‑leak, T‑H, access control and CCTV. Local alarm plus remote notification; power‑off & fire‑extinguishing linkage under fire risk to protect server hardware.

  6. Flexible power scheme for off‑grid remote sites Standard UPS backup power. Expandable PV solar input and diesel generator interface for mining & field locations with unstable municipal grid.

  7. High‑level customization & turn‑key project service Customizable container dimension, rack quantity, per‑rack power density, cooling method and enclosure protection grade. Full turn‑key service covering solution design, manufacturing, factory test and on‑site implementation.

Main Application Scenarios

  1. Edge computing: 5G edge node, urban edge computing computer room;

  2. Government‑enterprise disaster recovery: Off‑site backup disaster‑recovery room for public & private enterprises;

  3. Industrial field‑sites: Local data‑processing room for mine, oil‑gas and wind‑power stations;

  4. Temporary capacity expansion: IDC capacity upgrade, phased short‑term computing demand;

  5. Emergency deployment: Temporary data center for rescue & disaster‑relief missions.

Deployment & Operation‑Maintenance Notes

  1. Site preparation: Solid foundation with proper drainage to prevent water soaking container bottom.

  2. External interface: Supply matched‑rating mains power. For air‑cooled version reserve sufficient ventilation clearance; for water‑cooled version reserve cooling‑water pipe interface.

  3. Network: Deploy fiber‑optic network access to satisfy server data transmission bandwidth.

  4. O&M: Regular remote inspection via DCIM platform; inspect shell anti‑corrosion condition; periodically calibrate fire‑suppression cylinder pressure.

  5. Environment: Specify high‑cold / salt‑spray corrosive environment at selection phase for reinforced anti‑corrosion enclosure customization.